女朋友水太多进去就软了,伊人久久大香线蕉av影院,被十几根触手扒开腿猛戳动漫 ,暴露yín荡女友17部分

山東鼎勝制冷設備有限公司
地址:濟南天橋區粟山路泉利重配城
全國咨詢熱線:400-098-6610
電話:0531-85968762
手機:13075373251
聯系人:鄧老師
當前位置:首頁-新聞咨訊
新聞咨訊
三相電源安裝醫藥冷庫的安全性能
2017-11-06 18:32:54

1、使用測電筆或者萬用表檢查三相電源是否正常有無缺相或電壓異常,確認正常后合上電源總開。

1, the test pencil or a multimeter to check whether there is no normal three-phase power phase or abnormal voltage, confirm the normal close power drive.

2、選擇使用機組1或2,檢查相應電控箱面板上開關是否處于自動狀態,然后打開控制箱合上相應機組空開供電,相應的另一臺機組電控箱醫藥冷庫內電源必須處于斷開狀態以防兩臺機組同時工作超出電源供電線路負荷。

2, choose to use 1 or 2 units, whether in automatic mode switch check panel corresponding electric control box, and then open the control box on the corresponding unit air supply, another unit electric control box power corresponding must be disconnected to prevent two units at work beyond the power supply line load.

3、合上控制箱內空開后關上控制箱門查看控制箱面板電源指示燈是否正常點亮,并觀察數顯溫控與溫度記錄儀顯示溫度是否一致(相差0.5℃以內為正常)。

3, on the control box open closed control box door check control box panel power indicator light is normal, and the observation of digital temperature control and temperature recorder display temperature is consistent (up to 0.5 DEG C for normal).

醫藥冷庫廠家

4、對照電控箱說明書調整數顯溫控,設置參數為:上限溫度為7℃,下限溫度為3℃,超溫報警值為1,超溫報警延時為0,機組開機延時為3分鐘。

4. Adjust the digital display temperature control with the instruction of the electronic control box, set the parameters as follows: the upper limit temperature is 7 degrees, the lower limit temperature is 3 degrees, the overtemperature alarm value is 1, the overtemperature alarm delay is 0, the unit startup delay is 3 minutes.

二 溫度記錄儀設置及操作

Setting and operation of two temperature recorder

1、溫度記錄儀記錄間隔為15分鐘,上限為8℃下限為2℃,按鍵停止設置為禁止。

1, the temperature recorder recording interval is 15 minutes, the upper limit is 8 degrees, the lower limit is 2 degrees, the button is set to prohibit.

2、溫度記錄儀記錄容量為16000次,相對應每次間隔15分鐘總記錄時長為166天,所以每間隔165天必須把記錄儀連接電腦把儲存器內數據導入硬盤保存,保存后需重新設置一次以清除原來記錄儀內儲存器上的數據,重新設置后需重新按住記錄儀上按鍵5秒以上開啟記錄儀。(具體見記錄儀說明書)

2, temperature recorder capacity is 16000 times, corresponding to the time interval of 15 minutes total record length of 166 days, so every 165 days to put the recorder connected to the computer in the memory data into hard disk storage, save to reset once to remove the original recorder in storage device on the data, after the reset the need to hold the recorder button for 5 seconds on recorder. (see the recorder instructions)

本文由醫藥冷庫為您提供,我們的網站是:http://www.sddslk.com我們將以全心全意的熱情為您提供更優質的服務,歡迎您的訪問!

This article is provided by the pharmaceutical cold storage, our website is: http://www.sddslk.com, we will wholeheartedly provide you with better service, you are welcome to visit!

在線咨詢
主站蜘蛛池模板: 南投县| 建始县| 五莲县| 开封市| 株洲市| 隆林| 辽中县| 奉化市| 胶南市| 华安县| 藁城市| 仁布县| 博乐市| 自治县| 乳山市| 拜城县| 绵竹市| 都昌县| 台北县| 滁州市| 彭阳县| 涟水县| 宣化县| 肥城市| 巴青县| 保定市| 章丘市| 商水县| 疏附县| 揭东县| 临漳县| 广平县| 彝良县| 久治县| 泽州县| 宁晋县| 太白县| 宝山区| 铜陵市| 陵川县| 中宁县|